Model
Central mining cable

Item specifics

Fiber Type
G652D/G657/Multimode
Operating Temperature
-40°C to + 70°C
Installation
Aerial/Direct Buried/Duct
Transport Package
Wooden Drums or as Per Customers′ Requests

Review

Description

Description

MGXTSWV Central mining cable , the fibers,200μm or 250μm, are positioned in a loose tube made of a high modulus plastic. The tubes are filled with a water-resistant filling compound. The tube is wrapped with a layer of PSP longitudinally. Between the PSP and the loose tube water-blocking material is applied to keep the cable compact and watertight. Two parallel steel wires are placed at the two sides of the steel tape, over a thin inner PE sheath, the cable is completed with a polyethylene (PE) outer sheath.

Characteristics

·Good mechanical and temperature performance

·High strength loose tube has good performance of water proof and high strength

·Special tube filling compound ensure a critical protection of fiber

·Crush resistance.

·Two parallel steel wires ensure tensile strength

·PSP enhancing moisture-proof and anti rodent

·Good water resistance material prevent longitudinal seepage

·Blue flame retardant PVC as second sheath to make the cable has good flame retardant performance.

Standards

·MGXTWV cable complies with Standard MT386-1995 test method and decision rule of the flame retardant of the cable used in coal mine.

Optical Characteristics

G.652

G.655

50/125μm

62.5/125μm

Attenuation 

(+20℃)

@850nm

≤3.0dB/km

≤3.0dB/km

@1300nm

≤1.0dB/km

≤1.0dB/km

@1310nm

≤0.36dB/km

≤0.36dB/km



@1550nm

≤0.22dB/km

≤0.22dB/km

Bandwidth(Class A)

@850

≥500MHZ·km

≥500MHZ·km

@1300

≥1000MHZ·km

≥600MHZ·km

Numerical Aperture

0.200±0.015NA

0.275±0.015NA

Cable Cut-off 

Wavelength λcc

≤1260nm

≤1480nm

Technical Parameters

Cable Type

Fiber Count

Cable Diameter

mm

Cable Weight

Kg/km

Tensile Strength 

Long/Short 

Term N

 Crush Resistance

Long/Short 

Term N/100m

Bending Radius 

Static/Dynamic 

mm

MGXTSWV-2~12

2~12

11

130

500/1000

500/1500

15D/30D

Storage/Operating Temperature : -40℃ to + 70℃