FCJ factory Air-blown Fiber Optic Cable 48 96 core g652d micro duct air-blown fiber Outdoor Optic Cable
FCJ factory Air-blown Fiber Optic Cable  48 96 core g652d micro duct air-blown fiber   Outdoor Optic Cable
FCJ factory Air-blown Fiber Optic Cable  48 96 core g652d micro duct air-blown fiber   Outdoor Optic Cable
FCJ factory Air-blown Fiber Optic Cable  48 96 core g652d micro duct air-blown fiber   Outdoor Optic Cable
FCJ factory Air-blown Fiber Optic Cable  48 96 core g652d micro duct air-blown fiber   Outdoor Optic Cable
FCJ factory Air-blown Fiber Optic Cable  48 96 core g652d micro duct air-blown fiber   Outdoor Optic Cable
Model
Air-blown cable

Item specifics

Number of Conductors
≥ 10
Fiber Type
G652D/Multimode
Armored
Yes
Operating Temperature
-40°C to + 70°C
Installation
Aerial/Direct Buried/Duct
Transport Package
Wooden Drums or as Per Customers′ Requests

Review

Description

Description

Air-blown Fiber Optic Cable ,Large core number air blowing cable GYFY cable structure is the phi 250 mu m optical fibers are jacketed high modulus material made of loose tube, the loose casing pipe is filled with waterproof compound, loose tube around the center of the strengthen core twist synthetic compact round cable core, the cable core gap mid to moisture-proof waterproof yarn, then extruding PE sheathed cable.

Characteristics

·Small outside diameter, light weight, easy to lay.
·Adopt semi dry structure, construction is clean and tidy.
·Loose tube material itself has a good water resistance and high strength.
·special tube filling compound ensure a critical protection of fiber.
·Adopt the following measures to ensure the waterproof performance of the optical cable.
·Loose tube filled with special waterproof compound.
·Using dry type of water blocking material, the whole section of water resistance, to prevent the optical cable vertical seepage.

Standards

· Using microtubule resources, especially for the backbone network, access network and fiber to the home.
· Cabling costs are low and suitable for upgrading the old city and building network.

Optical Characteristics

G.652

G.655

50/125μm

62.5/125μm

Attenuation
(+20℃)

@850nm

≤3.0 dB/km

≤3.0 dB/km

@1300nm

≤1.0 dB/km

≤1.0 dB/km

@1310nm

≤0.36 dB/km

≤0.40 dB/km

@1550nm

≤0.22 dB/km

≤0.23dB/km

Bandwidth

(Class A)

@850nm

≥500 MHz·km

≥200 MHz·km

@1300nm

≥1000 MHz·km

≥600 MHz·km

Numerical Aperture

0.200±0.015NA

0.275±0.015NA

Cable Cut-off Wavelength

≤1260nm

≤1480nm

Technical Parameters

Cable Type

Fiber Count

Cable Diameter
mm

Cable Weight kg/km

Tensile Strength
Long/Short Term N

Crush Resistance
Long/Short Term N/100mm

Bending Radius
Static/Dynamic
mm

GYFTY

2-60

5.0

20

1100/550

150/500

30D/15D

GYFTY

62-72

5.5

25

1100/550

150/500

30D/15D

GYFTY

74-96

6.7

32

1700/850

150/500
30D/15D

Storage/Operating Temperature : -40℃ to + 70℃