FCJ factory Ribbon Optical Fiber 8F (G. 657. A1) Single-Mode For Multi-Core Fiber Optic Cable
- Model
- Ribbon Optical Fiber (G. 657. A1)
Item specifics
- Fiber Type
- G.657.A1
- Operating Temperature
- -40°C to + 70°C
- Installation
- Aerial/Direct Buried/Duct
Review
Description
Bend Insensitive Single-mode Optical Fiber (G.657.A1)
The Ribbon Optical Fiber complie with or exceed the technical specifications in ITU-T G.657.D /A1.
- Superior anti-bending property;
- Fully compatible with G.652 single-mode fiber. Full band (1260~1626 nm) transmission;
- Low PMD for high bit-rate and long distance transmission. Extremely low micro-bending attenuation, applicable for all optical cable types including ribbons;
- High anti-fatigue parameter ensures service life under small bending radius.
All cable constructions, 1260~1626nm full band transmission, FTTH high speed optical routing, optical cable in small bend radius, small-size optical fiber cable and device, L-band.
Fiber color code | 1 | 2 | 3 | 4 | 5 | 6 |
Blue | Orange | Green | Brown | Slate | White* | |
7 | 8 | 9 | 10 | 11 | 12 | |
Red | Black | Yellow | Purple | Pink | Aqua |
*The Color also be natural
The optic fiber adopts G.657 series coated optic fiber, and a tight jacket layer composed of a suitable thermoplastic material is added to the outside. It has a mechanical buffer protection effect on the coated optic fiber and is easy to strip from the light;
The optic cable adopts aramid tow or the glass yarn is used as a strengthening member, and they are evenly twisted in layers or placed longitudinally outside the optic fiber tight jacket;
The optic cable is extruded with a layer of circular polyurethane (TPU) sheath outside the strengthening member.
Attributes | specification | ||
Dimensional Specifications | Cladding Diameter | 125.0±0.7 um | |
Cladding Non-Circularity | ≤0.7 % | ||
Coating Diameter | 243±7 um | ||
Coating-Cladding Concentricity | ≤10 um | ||
Coating Non-Circularity | ≤6 % | ||
Core-Clad Concentricity | ≤0.5 um | ||
Fiber curl (radius) | ≥4 m | ||
Delivery length | 2.1-50.4( km/reel) | ||
Optical Specifications Optical Specifications | Mode-Field Diameter (MFD) | @1310nm | 8.8±0.4 um |
@1550nm | 9.8±0.6 um | ||
Attenuation | @1310nm | ≤0.35 dB / km | |
@1383nm | ≤0.35 dB / km | ||
@1550nm | ≤0.21 dB / km | ||
@1625nm | ≤0.23 dB / km | ||
Attenuation VS. Wavelength | @1285-1330nm, Ref. λ@1310nm | ≤0.03 dB / km | |
@1525-1575nm, Ref. λ@1550nm | ≤0.02 dB / km | ||
Point Discontinuity | @1310nm | ≤0.04 dB | |
@1550nm | ≤0.04 dB | ||
Polarization Mode Dispersion(PMD) | Maximum Individual Fiber PMD | ≤0.1 ps/(km1/2) | |
PMD Link Design Value (M=20, Q=0.01%) | ≤0.06 ps/(km1/2) | ||
Typical Value | 0.04 ps/(km1/2) | ||
Zero Dispersion Wavelength(λ0) | 1312±12 nm | ||
Zero Dispersion slope(S0) | ≤0.092 ps/(nm2.km) | ||
Dispersion | 1550nm | ≤18 ps/(nm.km) | |
1625nm | ≤22 ps/(nm.km) | ||
Cable cutoff wavelength λcc | ≤1260 nm | ||
Mechanical Specifications | Proof test | ≥9.0N, ≥1.0%, ≥100Kpsi | |
Dynamic stress corrosion susceptibility parameters Nd | ≥20 | ||
Coating strip force | Average | 1.5 N | |
Peak | 1.3-8.9 N | ||
Macrobend loss | 1 turn Φ20mm@1550nm&1625nm | ≤0.5 dB,≤1.0 dB | |
10 turns Φ30mm@1550nm&1625nm | ≤0.15 dB,≤0.75 dB | ||
100 turns Φ50mm@1310nm&1550nm&1625nm | ≤0.01 dB | ||
Environmental Specifications | Temperature Dependence (-60ºC to +85ºC,@1310nm&1550nm&1625nm) | ≤0.05 dB / km | |
Temperature Humidity Cycling (-10ºC to +85ºC, at 85%RH @1310nm&1550nm&1625nm) | ≤0.05 dB / km | ||
Water Immersion (23±5ºC, 30 days@1310nm&1550nm&1625nm) | ≤0.05 dB / km | ||
Dry Heat Soak(85±2ºC, 30 days@1310nm&1550nm&1625nm) | ≤0.05 dB / km | ||
Damp Heat (85±2ºC at 85%RH, 30 days@1310nm&1550nm&1625nm) | ≤0.05 dB / km |